Microfluidic Automated Platforms

The VenaFluxTM Platform is the first semi-automated microfluidic platform capable of executing cell rolling, binding/adhesion and migration studies under shear flow mimicking in vivo flow rates.
Features:
- Robust and easy to use
- Ideal for use with whole blood for platelet adhesion, aggregation and thrombi formation (thrombosis); biofilm culture ove extended periods of time.
- Easy to study cell adhesion, migration and transmigration - more physiologically relevant than static assays.
- Excellent platform for in vitro studies and running experiments in parallel with animal models.
Applications:
- Functional cell-ligand and cell-cell interaction studies.
- Morphology analysis of cell adhesion and migration.
- Tracking of flowing, rolling and migrating cells.
- IC50 curves easily produced.
- Preclinical drug development and lead optimization.



Specifications
The following specifications relate to the key components of the VenaFlux Platform: Mirus Evo Nanopump, VenaFluxAssay Softwarea and Kima pump
Specifications relating to Microscopy Workstation, Temperature Control, Cell Analysis Software and PC Control vary depending on user application. Contact us for further information.
Mirus Evo Nanopump |
|
MutliFlow8 | Capable of executing up to 8 assays in parallel in Vena8 biochips resulting in an 8-channel syringe pump |
Shear Stress Range for cell suspension | 0.05 - 10 dyne/cm2; steps of 0.05 dyne/cm2 (100 mL syringe) |
Shear Stress Range for whole blood* | 2.25 - 450 dyne/cm2 (1 mL syringe) |
Volumetric Flow Rates | 100 nL/minute - 20 μL/minute (100 mL syringe) |
Dead Volume | 600 μL |
Sample Volume Increments |
|
Valve Switching Time | 30 ms max (at 20oC, 2hz, with air under 10psi pressure) |
Working Pressure | 30 psi - 2 bars maximum |
Linear Velocity Range** | 10 μm/s to 10 cm/s |
Flow Direction | Reversible |
Sample Volume Aspiration Accuracy | ±1% |
Shear Stress Accuracy | ±0.5% |
Sample Volume Aspiration Precision | <1% CV |
Shear Stress Precision | 0.5% CV |
External Trigger | 2 inputs and 2 outputs externall trigger for better operation with external units and softwares |
Software Control | Integrated VenaFlux Assay software |
Dimensions |
|
Weight |
|
*Considering human whole blood with a viscosity of 4.5 cP
**Given for the flow of distilled water in a microcapillary with dimensions: 400 mm (W) x 100 mm (D) x 20 mm (L)
VenaFluxAssay Software |
|
Kima pump | |
Volumetric Flow Rates | Perfusion mode: 15 - 35 mL/hr (*) +/- 4% |
Shear Stress Range | Perfusion mode: ~2.5 to ~6.5 dyne/cm2(**) |
Dead Volume | < 300 µL |
Working Pressure | 30 psi - 2 bars maximum |
Flow Direction |
|
Additional features |
|
Dimensions |
190mm x 85mm x 90mm (L x W x H) |
Weight |
< 800g (bottle and tubing not included) |
Conditions of use |
|